Some of the options described may not apply to this
instrument. Please check the functions of the
instrument you have purchased before proceeding.
Some of the options described may not apply to this
instrument. Please check the functions of the
instrument you have purchased before proceeding.
Particular care should be taken not to over pressure the device
as this may rupture the sensor membrane. This is not covered
by the manufacturers warranty.
NOTE: The differential/gauge instruments will only measure positive
pressures i.e. positive pressure applied to the positive port, or
negative pressure applied to the negative port.
Particular care should be taken not to over pressure the device
as this may rupture the sensor membrane. This is not covered
by the manufacturers warranty.
NOTE: The differential/gauge instruments will only measure positive
pressures i.e. positive pressure applied to the positive port, or
negative pressure applied to the negative port.
INSTRUMENT APPLICATION
The range of 2000P instruments are suitable for gauge, differential,
or absolute measurements over a wide range of pressures. They are
not suitable for use with corrosive substances or cyclic
hydrocarbons, e.g. motor oil, transmission fluid and freon.
To use the 2000P with these components, isolation must be provided
in the form of a buffer, such as a mineral oil or dry air.
INSTRUMENT APPLICATION
The range of 2000P instruments are suitable for gauge, differential,
or absolute measurements over a wide range of pressures. They are
not suitable for use with corrosive substances or cyclic
hydrocarbons, e.g. motor oil, transmission fluid and freon.
To use the 2000P with these components, isolation must be provided
in the form of a buffer, such as a mineral oil or dry air.
GB
GB
INSTRUMENT OPERATION
BATTERIES
ON - OFF
ON OFF
Two AA or equivalent cells (not supplied). Follow instructions on
reverse of instrument for fitting/replacement.
When symbol appears on display, replace batteries.
Press key for on and key for off.
If key is held when unit is switched on,
automatic switch-off function will be disabled until the unit is switched
off.
IP65/IP67 RATING
LOG
MAX/MIN
The waterproof rating for this product will not be maintained unless
the screws holding the battery compartment are firmly tightened
when inserting or replacing batteries.
Automatic switch-off after
12 minutes, unless any key is activated or the instrument is in
or mode.
INSTRUMENT OPERATION
BATTERIES
ON - OFF
ON OFF
Two AA or equivalent cells (not supplied). Follow instructions on
reverse of instrument for fitting/replacement.
When symbol appears on display, replace batteries.
Press key for on and key for off.
If key is held when unit is switched on,
automatic switch-off function will be disabled until the unit is switched
off.
IP65/IP67 RATING
LOG
MAX/MIN
The waterproof rating for this product will not be maintained unless
the screws holding the battery compartment are firmly tightened
when inserting or replacing batteries.
Automatic switch-off after
12 minutes, unless any key is activated or the instrument is in
or mode.
Models
Models
Models
Models
Operating Range
Operating Range
Overrange
Overrange
Features
Features
FEATURES
FEATURES
RANGE
RANGE
2000P, 2001P, 2002P, 2003P, 2005P
2000P, 2001P, 2002P, 2003P, 2005P
2020P, 2021P, 2022P, 2023P, 2024P, 2025P, 2026P
2020P, 2021P, 2022P, 2023P, 2024P, 2025P, 2026P
2080P, 2081P, 2082P, 2083P, 2084P, 2085P, 2086P
2080P, 2081P, 2082P, 2083P, 2084P, 2085P, 2086P
25mbar / 10 HO
2
25mbar / 10 HO
2
Backlight, Out of Range, Zeroing,
Zeroing Absolute & Hold
Backlight, Out of Range, Zeroing,
Zeroing Absolute & Hold
350mbar / 140 H O
2
350mbar / 140 H O
2
130mbar / 52 H O
2
130mbar / 52 H O
2
As above plus: Smoothing, Units of Pressure,
Rangelock & Max/Min
As above plus: Smoothing, Units of Pressure,
Rangelock & Max/Min
1bar / 401 H O
2
1bar / 401 H O
2
2bar / 28 PSI
2bar / 28 PSI
As above plus: Manuallog and Autolog
As above plus: Manuallog and Autolog
4bar / 58 PSI
4bar / 58 PSI
7bar / 101.5 PSI
7bar / 101.5 PSI
10bar / 145 PSI
10bar / 145 PSI
External Transducer
External Transducer
-
-
2bar absolute
2bar absolute
10bar / 145 PSI
10bar / 145 PSI
10.342bar / 150 PSI
10.342bar / 150 PSI
4bar
4bar
2000P, 2020P, 2080P
2000P, 2020P, 2080P
2001P, 2021P, 2081P
2001P, 2021P, 2081P
2002P, 2022P, 2082P
2002P, 2022P, 2082P
2003P, 2023P, 2083P
2003P, 2023P, 2083P
2024P, 2084P
2024P, 2084P
2005P, 2025P, 2085P
2005P, 2025P, 2085P
2026P, 2086P
2026P, 2086P